Misc. Products & Accessories

DPM-3332

It measures DC : -20 to 20A (bidirectional) , 5.0 to 60V or 0 to 60V with LCD displays Max & Min V , I . Registers WH , Ah and operational time in Hr., Min & Sec.

SSB-6113

12/24VDC selectable, 120A, IP67. The Programmable Battery Protector protects the starter battery from being over discharge. Programmable disconnect voltage set poing range from 9.0 to 16.0V by 0.1V step.

VWM-4108

This controller is suitable for any 12VDC system up to 8A

DPA-3051 G2

The Data Adapter DPA-3051 G2 is specially made for downloading data from Manson DPM Digital Power Meters using USB 2.0 connection. Supplied with software for graphical analysis and data acquisition to PC.

DPM–3221 G2 for use with external shunt

It is designed for use with external shunt of 50 mV rating. Voltage range : 5 – 60V or 0 – 60V Current range : depends on the rating of shunt ; 0-50A, 0-100 A , 0 – 200A LCD displays Max & Min V , I . Registers WH , Ah and operational time in Hr., Min & Sec.

DPM-3232 G2 with built in shunt

It measures DC : 0-20A , 5.0- 60V or 0 – 60V with LCD displays Max & Min V , I . Registers WH , Ah and operational time in Hr., Min & Sec.

USB-2928

Input AC voltage range: 100~240Vac 50~60Hz Output DC voltage: 5Vdc 2A maximum 8 outputs Auto-select between iPad, iPhone and Android base devices

SSB-5113

12/24VDC selectable 120Amp IP67 Dual Battery Programmable Isolator for vehicle's application. Automatic control connect and isolate bwteen Main battery and second battery or load.

DPM-3232 with built in shunt

It measures DC : 0-20A , 5.0- 60V or 0 – 60V with LCD displays Max & Min V , I . Registers WH , Ah and operational time in Hr., Min & Sec.

DPM–3221 for use with external shunt

It is designed for use with external shunt of 50 mV rating. Voltage range : 5 – 60V or 0 – 60V Current range : depends on the rating of shunt ; 0-50A, 0-100 A , 0 – 200A LCD displays Max & Min V , I . Registers WH , Ah and operational time in Hr., Min & Sec.

DPA-3051

It is especially designed for use with Manson DPM meters for getting data stored at DPM . Supplied with software for graphical analysis and data acquisition to PC.

DPA-3015 (50A) / 3016 ( 100A) / 3018 ( 200A)

High precision Manganin shunt with 50mV rating. It comes with 5 m. Kelvin 4 sensing cable and RJ-11 interconnection configured to DPM -3221 for quick installation.

SSB-2112 ( 12V, 100A), SSB-2212 ( 24V, 100A)

These all solid state programmable relays are designed to connect two batteries from a single charging source and separate the batteries to avoid the main (starting) battery discharges to the second battery at selected settings. There are 10 sets of disconnect and reconnect voltage for selection.

SSB – 4112 (12V,100A), SSB- 4212 ( 24V, 100A)

These are solid state with programmable low voltage disconnects made to protect your battery from over discharge. There are 10 sets of Disconnect Voltage & Reconnect Voltage for selection .

SBC - 1120 ( 12 V), SBC – 1220 ( 24

These sealed MCU control modules are designed to use any solenoid switches which use less than 1.5A coil current . They allow a much wide range of solenoid switch selection for the right application .

MSE-9140

It automatically connects the Output to the back up battery when main power to the equipment is lost . When main power is restored it reconnects and float charge battery.

MS-928 25A, 12V DC system, MSE-9140 40A, 12V DC system

It automatically connects the Output to the back up battery when main power to the equipment is lost . When main power is restored it reconnects and float charge battery.

HBR-3100

The HBR-3100 is designed to use with HBR series of battery chargers. It has display for charging stages , details of fault , total run time and output on-off and etc .

ABD-4120

The ABD-4120 is designed to use with high power Manson Battery Chargers : SBC-2130/2140/2150/2215/.2220/2225/2408/2410/2413 The LED and LCD indicators show the real time charging stages, voltages and faults.

ATS-5100

The temperature sensor is made for our battery chargers SBC series and our PV charger controllers SBC-6XXX and SBC-7XXX series.

ATS-5120

The temperature sensor is made for our battery chargers SBC series and our PV charger controllers SBC-6XXX and SBC-7XXX series.

HCR-3000

This remote controller has two 0-5V DC scalable control voltages, and On-Off control. It is suitable for Manson HCS series Power Supplies, SIM and SPS-9600 Power supply . It also can be used with other equipments which have DC Power Source of +5V and 50mA , and control circuit with IO and variable voltage and current with appropriate socket and pin convention .